Low Profile – 1600 Advantage Series Service Manual – International 
TROUBLESHOOTING GUIDE 
                                 MODEL 1633-000 EA   NATURAL GAS   230 VAC   50 HZ   1 PHASE 
                                 MODEL 1634-000-EA   L.P. GAS               230 VAC   50 HZ   1 PHASE 
 
 
NOTE: When checking components on left side of unit, be sure to check for proper 
connections in power connector, ( marked P. C. on schematic diagram ) located inside 
motor cover.  
 
SYMPTOM     
 
POSSIBLE CAUSE   
 
 
EVALUATION 
 
Oven fan will   
 
Incoming power supply   
Check breakers/ reset if required 
not run   
 
 
 
 
 
 
call Power company if needed 
 
 
 
 
Oven fan switch  
 
Check continuity between 
 
 
 
 
 
 
 
 
switch terminals. 
 
 
 
 
Thermostat, hi-limit 
 
Terminals are normally closed, if 
 
 
 
 
 
 
 
 
open, reset thermostat and test 
 
 
 
 
 
 
 
 
oven for proper operation. If it 
 
 
 
 
 
 
 
 
will not reset, replace thermostat. 
 
 
 
 
Fan fuse 
 
 
 
Check, replace if necessary. 
 
 
 
 
Fuse holder 
 
 
Check, replace if necessary. 
 
 
 
 
Oven fan relay   
 
Check for power to coil of oven 
 
 
 
 
 
 
 
 
fan relay. If no voltage is present, 
 
 
 
 
 
 
 
 
trace wiring back to hi-limit thermostat. 
 
 
 
 
 
 
 
 
Check for supply voltage at terminal 
 
 
 
 
 
 
 
 
#6 of the relay. If no voltage is present, 
 
 
 
 
 
 
 
 
trace wiring back to fuse holder. If  
 
 
 
 
 
 
 
 
voltage is present, at the relay coil, check  
 
 
 
 
 
 
 
 
to insure the contacts are closing. 
 
 
 
 
Capacitor(s) 
 
 
Check for opens, shorts, or grounds. 
 
 
 
 
Motor (s)    
 
 
Check for opens, shorts, or grounds. 
No control box cooling   
Fan switch 
 
 
(SEE OVEN 
 
 
 
 
Hi-limit   
 
 
  FAN WILL  
 
 
 
 
Oven fan relay   
 
NOT RUN.) 
 
 
 
 
Cooling fan(s)   
 
Supply voltage should now be at these 
 
 
 
 
 
 
 
 
motors. If voltage is present, check 
 
 
 
 
 
 
 
 
motor for open, shorts, or grounds. 
 
 
 
 
 
 
 
 
WITH POWER OFF: check for 
 
 
 
 
 
 
 
 
locked rotor. 
No automatic control 
 
Incoming power supply   
Check circuit breakers, reset if needed. 
box cooling 
 
 
 
 
 
 
Call power company if needed. 
 
 
 
 
Cooling fan thermostats  
Thermostat closes at 120
°
F and 
 
 
 
 
 
 
 
 
opens at 100
°
F. With the cooling  
 
 
 
 
 
 
 
 
fan thermostat preheated, check 
 
 
 
 
 
 
 
 
for continuity. If switch is open, replace. 
 
 
 
 
Cooling fan(s)   
 
Supply voltage should now be at these 
 
 
 
 
 
 
 
 
motors. If voltage is present, check 
 
 
 
 
 
 
 
 
motor for opens, shorts or grounds. 
 
 
 
 
 
 
 
 
WITH POWER OFF: Check for  
 
 
 
 
 
 
 
 
locked rotor. 
 
Oven will not heat 
 
Gas supply 
 
 
Check for adequate gas supply to oven. 
 
 
 
 
Manual gas shut off valve 
 
Check to see that the manual gas shut 
 
 
 
 
 
 
 
 
off  valve is open. 
 
 
 
 
Fan switch 
 
 
Check to see that the fan switch is on. 
 
 
 
 
Main oven fan   
 
Check if main oven fan is operating. 
 
 
 
 
 
 
 
 
if not, refer to “oven fan will not run”. 
           NOTE: These ovens utilize 2 complete Burner/Temperature control systems. Each system will 
           Follow the same troubleshooting sequence.  
 
 
 
 
Fuse, burner 3A. 
 
 
Check, replace if necessary.