MODEL 1629-000-A     224/415 VAC   50HZ 
 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a five conductor service. 
Brown conductor is hot. 
Black conductor is hot. 
Black conductor is hot. 
Blue conductor is neutral. 
Green conductor is ground. 
CONTROL BOX 
AUTO COOL DOWN 
When the temperature in either one of the control boxes reaches 120
°
±
3
°
 (49
°
±
 
1.7
°
), the cooling fan thermostats will switch power to the cooling fans. The thermostats 
will interrupt power to the cooling fans when the temperature falls to 100
°
±
 3
°
 (37
°
±
 
1.7
°
MAIN FAN CIRCUIT 
Line voltage is permanently supplied (through a power filter) to a normally open contact of 
the oven power switch. Line voltage is permanently supplied to the two normally open 
cooling fan thermostats. Closing the oven power switch supplies line voltage, through both 
normally closed control box hi-limit thermostats, to the oven power relay. Its contacts now 
close supplying line voltage to the two main fan motors. Closing the oven power switch also 
supplies line voltage to the control box cooling fans, the oven control, the control 
transformer, and the conveyor motor. 
TEMPERATURE 
CONTROL 
Closing the oven power switch supplies line voltage, through the 10 amp. fuse, through the 
oven power relay, to the primary of the control transformer. 24VAC is supplied to the oven 
control. The oven control is set to desired temperature. The thermocouple will provide 
varying millivolts to the oven control. The oven control supplies line voltage to the contactor 
at intermittent intervals to maintain desired temperature. The display on the oven control 
will indicate when the contactor is energized. 
NOTE: The display also indicates oven temperature. 
CONVEYOR DRIVE 
Closing the oven power switch supplies line voltage, through the 10 Amp fuse, through the 
oven power relay to the conveyor motor and to the primary of the control transformer. 
Secondary voltage, 24VAC, is supplied to the oven control. Setting the oven control to the 
desired time, outputs voltage, through a reversing switch, to the conveyor motor 
NOTE: The conveyor system uses a magnet and hall effect sensor to prove operation of 
the conveyor motor. If the conveyor motor is not running, “BELT JAM” is indicated on the 
display. 
AUTOMATIC COOL 
DOWN 
When the oven is started, the time delay relay timing circuit is enabled, permitting the oven 
fans to operate for approximately 20 minutes after the oven is shut off, to cool the oven. 
The time delay relay will keep the coil of the motor relay closed, maintaining operation of 
main fan and cooling motors.