Lincoln 1100 Series Manuel D’Utilisation

Page de 92
as follows:
220V -  30 ohms approximately
240V -  36 ohms approximately
Oven heats with switch off
Mercury Contactor
The mercury contactor has probably
malfunctioned in the closed position.  If
there is no voltage to the operating coil,
but there is high voltage at the contactor
output, replace the mercury contactor.
Intermittent Heating
Thermal/Overload
The main fan motor is equipped with
of motor
internal thermal protection and will
cease to operate if overheating
occurs.  As the motor overheats and
then cools, this will cause the oven to
cycle on and off intermittently.  This
may be caused by improper ventilation
or preventative maintenance.  Also,
most of the problems listed under
“Oven will not heat” can cause
intermittent failure.
Conveyor will not run
REFER TO PAGE 31
Conveyor speed varying
REFER TO PAGE 32
or intermittent
Time/Temp Display
REFER TO PAGE 33
inoperative
Temp Display out or
REFER TO PAGE 33
inaccurate
Impinger II - 1100 Series Service Manual - International
36