Lincoln 1628-000-A Manuel D’Utilisation

Page de 24
 
 
Low Profile – 1600 Series Adv Dig Electric S.M. – Int’l 
 
TROUBLESHOOTING GUIDE 
                                                       
 
MODEL 1621-000 EA      230/400 VAC   50 HZ   3 PHASE 
MODEL 1628-000 A         220/380 VAC   50 HZ   3 PHASE 
MODEL 1629-000 A         240/415 VAC   50 HZ   3 PHASE 
NOTE: When checking components on left side of unit, be sure to check for proper connections in power 
connector, (marked P. C. on schematic diagram) located inside motor cover.  
 
SYMPTOM 
POSSIBLE CAUSE 
EVALUATION 
Incoming power supply
 
Check breakers/ reset if required call Power company 
if needed.
 
Fuse, 10 A., main fan   
Check, replace if necessary. 
Fuse holder 
Check, replace if necessary. 
Filter, Power 
Check for supply voltage to filter. If there is no voltage, 
trace wiring back to fuse holder. If there is power in to 
the filter, but no power out, replace the filter. 
Oven fan switch
 
Check continuity between switch terminals.
 
20 minute time delay relay 
Check for supply voltage to terminal #1 and #3, if 
there is no voltage, trace wiring back to the power 
filter. If voltage is present, check for supply voltage at 
terminals #3 to #6, if no voltage is present, trace 
wiring back to on/off switch. If there is voltage at #3 
and #6, check for voltage at terminals #1 and #2, of 
there is no voltage at Terminals #1 and #2, replace 
the 20 minute time delay relay.  
Relay, main fan motors 
Check for power to coil of motor relay. If no voltage is 
present, trace wiring back to 20 minute time delay 
relay. Check for supply voltage to the contact of the 
relay. If no voltage is present, trace wiring back to 
power filter. If voltage is present, at the relay coil, 
check to insure the contacts are closing. Replace 
relay as needed. 
Hi-limit thermostat(s),  control 
box  
Terminals are normally closed, if open, reset 
thermostat and test oven for proper operation. If it will 
not reset, replace thermostat. 
Capacitor(s) 
Check for opens, shorts, or grounds. 
Oven fan will not 
run
 
Motor(s), main fan 
Check for opens, shorts, or grounds. 
No main fan cool 
down 
20 minute time delay relay 
Check for supply voltage at terminals #1 and #2 while 
is “ON”. Turn “OFF” the main fan switch, supply 
voltage should continue to be present for 20 minutes. 
If voltage is not present for 20 minutes, replace 20 
minute time delay relay.  
Fan switch 
(SEE OVEN FAN WILL NOT RUN.) 
Hi-limit thermostat(s) 
Terminals are normally closed, if open, reset 
thermostat and test oven for proper operation. If it will 
not reset, replace thermostat. 
Relay, main fan motors 
Check for power to coil of oven fan relay. If no voltage 
is present, trace wiring back to hi-limit thermostat. 
Check for supply voltage to the contact of the relay. If 
no voltage is present, trace wiring back to fuse holder. 
If voltage is present, at the relay coil, check to insure 
the contacts are closing. Replace relay as needed. 
No control box 
cooling
 
Cooling fan(s) 
Supply voltage should now be at these motors. If 
voltage is present, check motor for open, shorts, or 
grounds. WITH POWER OFF: check for locked rotor. 
No automatic 
control box cooling 
Incoming power supply 
Check circuit breakers, reset if needed. Call power 
company if needed.