AKER
Connection to the Water Supply
 
- Figures 23, 24
1.  Install the shut-off valve, water filter and 
automatic shut-off device as required. 
Note
The solenoid valve is located at the rear of 
your unit.
2.  Place a 1/4" OD copper tubing between the 
shut-off valve and solenoid valve. Make sure 
there is approximately 30" (70 cm) of excess 
tubing behind the unit for easy connection.
IMPORTANT
The solenoid valve has a Metric R3/4 male 
connection. 
A R3/4(metric) to a 1/4" OD adapter and 
cable clip are supplied with the icemaker.
 Figure 
24: Remove the cover cap (4) from 
the solenoid valve (1). Install the connection 
bracket (2) with sealing ring (6) on the 
solenoid valve (1). Attach the copper tube to 
the connection bracket (2). Secure the copper 
tube (3) to the appliance using the cable 
clip (5).
3.  Open the shut-off valve for the water supply 
and check the entire water system for leaks. 
Before the appliance is used for the first time 
a licensed plumber should bleed air from the 
system.
4.  Insert the electrical plug for the combined 
winecooler/freezer into the electrical outlet 
(Figure 23).
5.  Move the combined winecooler-freezer into 
final position in the room.
Figure 23