Tools Required 
  ■
  Tape Measure.
  ■
  Chalk Line.
  ■
   Caulking Gun.
  ■
  Caulk (provided).
  ■
  Clam Lock Wrench (provided).
  ■
  Level.
  ■
  Screw Driver. 
  ■
  Shims. 
Pre-Assembly 
Some panels have been protected with a strip-
pable film to prevent surface damage. Remove this 
film before assembly. It is very difficult to remove it 
from the panel edges after panels have been joined 
together. Note: Do not store panels with protective 
film in sunlight or high temperature areas for an 
extended period of time.
Placing the Utility Cooler 
This utility cooler should not be installed tight 
against any building or adjacent cooler wall. A
minimum of two inches must be provided for air 
circulation. Shims for leveling the floor must
also be incorporated into overall height and  
clearance requirements. 
Remote Units: A minimum four inch clearance is 
required between the top of the utility cooler
and the ceiling of the building in which it is being 
installed.
Self-contained Units: Sufficient clearance above the 
cooler must be allowed for ceiling panel  
and condensing unit installation. For ventilation 
requirements, see page 7.
The Cam Lock Fastening Method 
This utility cooler utilizes the cam-lock fastening
method. (See illustration on below.)
Insert the cam lock wrench into the lock before the
panels are pushed together. Turn the handle Cam
Hole counterclockwise as far as it will go to fully 
cock the
cam. Note: The cam must be fully cocked to
assure proper locking. The panels should then be
pushed together tightly and locked by turning the
wrench clockwise.
Plugs are provided to insert in cam-lock holes after
final assembly.
3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2026
Rev 01.28.09
Preparing the Cabinet for Use
CAM
CAM
HOLE
MODEL NOS.
US4KP
US4KP
KEG CAPACITY
4
10
DIMENSIONS
EXTERIOR
(mm)
Length
47" (1194)
93" (2362)
Depth
47" (1194)
47" (1194)
Height
77" (1956)
79" (2007)
CONDENSING UNIT
1/3
1/2
FULL LOAD AMPS
8.5
10.2
MAX. FUSE
15
15
SHIPPING WEIGHT lbs. (kg)
700 (318)
1150 (522)
EXTERIOR
Floor: Stucco galvanized steel. Roof, Walls & Doors: Stucco galvanized steel painted grey.
INTERIOR
Floor: 16 gauge slip resistant stainless steell. Roof, Walls & Doors: 26 gauge stucco 
galvanized steel.
ELECTRICAL
115 V, 60 Hz. 1ph AC. Junction box provided.
PLUMbING
Evaporator condensate drains through access hole in wall. 20" x 1/2" I.D. drain line provided.
REFRIGERATION
R134a refrigerant. 
INSULATION
4" UL Class 1 urethane foam. Flame Spreading Rate: 25 or less.  
Smoke Develop Rating: 450 or less.
DOORS
Flush-mounted with cam-lift chrome hinges, automatic door closer, magnetic gaskets, chrome pull handle. Standard right 
hinged. Door size: 30" W x 55" H.
FEATURES
Light “ON” indicator in door. Light switch and fixture installed on evaporator. Thermometer furnished loose.
OPTIONAL ACCESSORIES
• Foor rack    • Keg shelf kit