Perlick US10KP Manuel D’Utilisation

Page de 12
7
Form No. Z2026
Rev 01.28.09
General Information
Electrical Requirements 
The package unit must be installed so that the wir-
ing conforms to, and is in accordance with National 
and Local Electrical Codes. (See Condensing Unit 
Data Plate for Electrical Specifications.
CAUTION: Do not attempt to operate the condens-
ing unit on any other power source than that listed 
on the unit data plate. See appropriate wiring dia-
gram on pages 9, 10 or 11.
Starting The Cooler   
Allow the empty utility cooler to operate 24 hours 
for a settling-out period before use.
Temperature Control   
The temperature control is located on the evapo-
rator housing. It is factory adjusted to maintain a 
temperature of approximately 34° F. cut out and 
40° F. cut in. Cut out temperatures lower than 34°F. 
are not advisable as excessive frost may accumu-
late on the evaporator.
If excessive frost does accumulate, the unit is 
operating at too cold a temperature. To defrost the 
evaporator, turn off the electrical power to the con-
densing unit or turn the control to a warmer posi-
tion to allow the fan motor to defrost it. The control 
should then be reset to a temperature that will not 
ice up the evaporator. A plastic drain hose should 
be attached to the drain pan of the evaporator and 
routed through the wall panel. A receptacle should 
be provided for accumulated condensing water or 
connect to a building drain facility.
Ventilation Requirements 
Air-cooled units must be furnished with sufficent 
ventilation to maintain their efficiency. The table  
at right indicates the minimum room size/cubic 
footage, only the space above the condensing  
unit can be used. When the room size is below 
minimum, some type of forced ventilation must  
be provided.
There should be nothing on or around the machin-
ery compartment area which will restrict the flow of 
room temperature air to the condenser or over the 
compressor.
Compressor H.P.
Natural 
Circulation Cu. 
Ft. Room Volume 
Needed
Forced Air  
Circulation C.F.M. 
Fresh Air Entering 
Room
1/3 to 1/2
600
220
Cleaning the Condensing Unit 
Inspect the machinery compartment every 60 days. 
A heavy accumulation of dirt and/or grease on 
the front of the condensing unit (radiator) must be 
cleaned off with a stiff brush or vacuum cleaner. be 
careful not to bend the aluminum fins on the con-
densing unit.
Warranty 
 
This Utility Cooler is fully warranted against defects 
in both material and workmanship for a period 
of one (1) year from date of sale. Defective parts 
must be returned to Perlick freight prepaid. All 
parts found to be defective upon inspection will be 
replaced on a no-charge basis, F.O.b. our factory. 
Perlick is not responsible for parts damaged by 
alteration, unauthorized service, accident or abuse. 
All costs incident to replacement, including labor, 
refrigerant, and/or loss of sales are incidental to 
this warranty and must be borne by the user.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.