Annex B Information 
 
The following design information is provided for your reference: 
 
1.  No modifications are allowed to this equipment that could alter the CE compliance 
2.  Ambient temperature:   
40 degrees Celsius (104 degrees Fahrenheit) – Maximum  
3.  Humidity range:     
50% relative humidity 
4.  Altitude: 
 
 
  Sea 
level 
5.  Environment: 
 
Clean, dust-free and non-explosive 
6.  Radiation: 
  None 
7.  Vibration: 
  Minimal, 
i.e. 
machine 
mounting 
8.  Special installation requirements: 
Clean, dry compressed air 1 cfm @ 60 psi   
  
   (1.7 
m³/hr 
4.14 
bar) 
9.  Allowable voltage fluctuation: 
 
 
+/- 10% 
10.  Allowable frequency fluctuation: 
Continuous 
+/- 1% 
Intermittent +/- 
2% 
11.  Nominal supply voltage: 
120/1/60 or 220/1/50 or 60 (Verify on serial number tag) 
12.  Earth ground type:   
TN (system has one point directly earthed through a 
protective conductor) 
13.  Power supply should include a neutral power connection. 
14.  Over-current protection is supplied in the blender control panel, but additional 
protection should be supplied by the user. 
15.  The plug on the power cord serves as the electrical disconnect device. 
16.  Unit is equipped with three-phase motors (driven by single phase motor drive cards). 
17.  Functional identification 
18.  Cable support may be required for power cord, depending on final installation. 
19.  No one is required to be in the interior of the electrical enclosure during the normal 
operation of the unit.  Only skilled electricians should be inside the enclosure for 
maintenance. 
20.  Doors can be opened with a screwdriver, but no keys are required. 
21.  Two-hand control is not required, or provided. 
22.  All hoppers should be moved around and set in place with a lift truck or equivalent. 
23.  There are no frequent repetitive cycles that require manual control
⎯repetitive 
functions are automatic while the blender is operating. 
24.  An inspection report detailing the functional test is included with the OL blender. 
25.  The machine is not equipped with cableless controls. 