Mitsubishi Electronics MELSEC-F Manuel D’Utilisation

Page de 504
J-12
3 Wiring
3.2 Applicable Cable and Terminal Tightening Torque
FX
3G
/FX
3U
/FX
3UC
 PLC User's Manual - Analog Control Edition
FX
3U
-4AD-PTW-ADP (4-channel Platinum Resistance Thermometer Data Input)
3.2
Applicable Cable and Terminal Tightening Torque
Use the following cables to connect with the counterpart equipment. Terminate the cable end as shown below.
To connect the platinum resistance thermometer sensor, use the cable supplied with the Pt100 platinum
resistance thermometer or a twisted pair shielded cable.
1. Cables
Applicable cable and tightening torque
2. Termination of cable ends
To terminate the cable, treat the stranded/single wire directly or use a rod terminal with insulation sleeve.
• To directly terminate the end of a stranded/single-wire cable:
- Twist the end of the stranded cable so that the "barbed wires" 
cannot protrude.
- Do not solder-plate the end of the cable.
• To terminate cable end using a rod terminal with insulation sleeve:
If the cable sheath is too thick, it may be difficult to insert the cable into
the insulation sleeve. For this reason, select an appropriate cable while
referring to the external view.
3. Tool
• To tighten terminals, use a small-sized screwdriver whose head is straight and is not widened as shown in 
the figure to the right.
Note:
If the diameter of screwdriver grip is too small, tightening torque will not
be able to be achieved. Use the following recommended screwdriver or
an appropriate replacement (grip diameter: approximately 25mm).
Wire size
(stranded/single-wire)
Tightening 
torque
Termination
Single-wire 0.3mm
2
 to 0.5mm
2
(AWG22 to 20)
0.22 N
m to
0.25 N
m
• To connect a stranded cable, peel the cover off the cable 
and then twist the core before connection.
• To connect a single-wire cable, just strip the cover off the 
cable before connection.
2-wire
0.3mm
2
 (AWG22)
Rod 
terminal 
with 
insulation 
sleeve
0.3mm
2
 to 0.5mm
2
 
(AWG22 to 20)
(Refer to the rod terminal 
external view shown in 
the following figure.)
• Rod terminal with insulation sleeve
(recommended terminal)
AI 0.5-8WH : Manufactured by Phoenix Contact
• Caulking tool
CRIMPFOX ZA 3 : Manufactured by Phoenix Contact
(or CRIMPFOX UD 6 : Manufactured by Phoenix Contact)
Manufacturer
Model
Caulking tool
Phoenix Contact
AI 0.5-8WH
CRIMPFOX ZA 3
(or CRIMPFOX UD 6)
Manufacturer
Type
Phoenix Contact
SZS 0.4 
× 2.5
9mm
Termination of cable end
(0.35")
8mm    (0.31")
Contact area
(Crimp area)
14mm
2.6mm
(0.1")
Insulation sleeve
(0.55")
0.4mm
2.5mm
The head
should be
straight.
(0.01")