Mitsubishi Electronics MELSEC-F Manuel D’Utilisation

Page de 504
B-13
3 Wiring
3.2 Cable and Terminal Tightening Torque
A
Comm
on I
te
ms
B
FX
3U
-4AD
FX
3UC
-4
A
D
C
FX
3U
-4A
D
-A
D
P
D
FX
3G
-2A
D
-BD
E
FX
3U
-4DA
F
FX
3U
-4D
A
-AD
P
G
FX
3G
-1D
A
-BD
H
FX
3U
-3
A-
ADP
I
FX
3U
-4
A
D
-P
T
       
         
   -
A
D
P
J
FX
3U
-4A
D
-P
TW
     
        
      -
A
D
P
FX
3G
/FX
3U
/FX
3UC
 PLC User's Manual - Analog Control Edition
FX
3U
-4AD/FX
3UC
-4AD (4-channel Analog Input)
3.2.3
Cable (FX
3UC
-4AD)
Use the following cables to connect with counterpart equipment. Terminate the cable end as shown below.
1. Cable
Applicable cable and tightening torque
2. Termination of cable end
To terminate the cable, treat the stranded/single-wire directly or use the rod terminal with insulation sleeve.
• To directly terminate end of stranded/single-wire cable:
- Terminate the end of the stranded cable so that the "barbed wires" 
cannot protrude.
- Do not solder-plate the end of the cable.
• To terminate cable end using rod terminal with insulation sleeve:
If the cable sheath is too thick, it may be difficult to insert the cable
into the insulation sleeve. For this reason, select an appropriate cable
while referring to the external view.
3. Tool
• To tighten terminals, use a purchased small-sized screwdriver whose head is straight and is not widened 
as shown in the right figure.
Note:
If the diameter of screwdriver grip is too small, tightening torque will not
be able to be achieved. Use the following recommended screwdriver or
an appropriate replacement (grip diameter: approximately 25mm).
Wire size (stranded/
single-wire)
Tightening 
torque
Termination
Single wire
0.3mm
2
 to 0.5mm
2
(AWG22 to 20)
0.22N
m to 
0.25N
m
• To connect a stranded cable, peel the cover off the cable
and then twist the core before connection.
• To connect a single-wire cable, peel the cover off the
cable before connection.
Double wire
0.3mm
2
(AWG22)
Rod terminal 
with 
insulation 
sleeve
0.3mm
2
 to 0.5mm
2
(AWG22 to 20)
(Refer to the external 
view of rod terminal 
shown in the following 
figure.)
• Rod terminal with insulation sleeve
(recommended terminal)
AI 0.5-8WH : Manufactured by Phoenix Contact
• Caulking tool
CRIMPFOX ZA 3 : Manufactured by Phoenix Contact
(or CRIMPFOX UD 6 : Manufactured by Phoenix Contact)
Manufacturer
Model
Caulking tool
Phoenix Contact
AI 0.5-8WH
CRIMPFOX ZA 3
(or CRIMPFOX UD 6)
Manufacturer
Model
Phoenix Contact
SZS 0.4
×2.5
9mm
Termination of cable end
(0.35")
8mm    (0.31")
Contact area
(Crimp area)
14mm
2.6mm
(0.1")
Insulation sleeve
(0.55")
0.4mm
2.5mm
The head
should be
straight.
(0.01")
(0.09")