PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
L/R SPRAY OZ/M
This function allows the operator to view or to enter 
the actual flow rate coming out of the sprayhead for 
each side of the brewer. This is NOT used to control 
the actual flow rate, but to tell the internal controller 
how fast the water is flowing.
Procedure  to  adjust  the  sprayhead  flow  rate  set-
ting:
1.  Press and hold the right hidden button until the 
display reads SET LANGUAGE. Press the right hid-
den button until the display reads L SPRY OZ/M
The number represents what the brewer thinks is 
the flow rate out of the left sprayhead.
2.  If the actual flow rate of the sprayhead is known 
but is different than the number on the display, use 
the (-) and (+) to enter the correct flow rate.
3.  Press  and  release  DONE.  The  display  will  now 
read R SPRY OZ/M. The number represents what 
the brewer thinks is the flow rate out of the right 
sprayhead.
4.  Repeat step #2 for the right sprayhead.
5.  When finished, press and release DONE to advance 
to the next function screen, L BYPS OZ/M:  XX.X. To 
exit programming and return to the MAIN SCREEN
press and release either ON/OFF pad.
R SPRY  OZ/M:  XX.X
(-)      DONE      (+)
L SPRY  OZ/M:  XX.X
(-)      DONE      (+)
L BYPS  OZ/M:  XX.X
(-)      DONE      (+)