The  electrical  connection  should  be  made 
using a double pole isolating switch (cooker 
socket) with at least 3mm contact separation 
in  all  poles.    The  cable  must  have 
conductors  of  sufficiently  high  cross-
sectional  area  to  prevent  overheating  and
 
deterioration. 
The recommended cross-section area is six 
square millimetres (6.00mm
2
).  
The  cable  should  be  routed  away  from 
potentially  hot  areas  marked  by  X.    See 
Fig.1. 
To move the appliance, open the  oven door, 
and  lift  the  appliance  by  holding  inside  the 
top of the compartment.  See Fig.2. 
This is a type X appliance, which means it is 
free-standing and can be fitted with cabinets 
on one or both sides.   
Side walls which are above hob level should 
be  protected  by  heat  resistant  non-
combustible  material  and  MUST  NOT  be 
nearer than 40mm to the hob side. 
A  nominal  air  gap  of  2mm  at  either  side  of 
the  appliance  is  required  to  enable  the 
appliance to be moved into position.  
Always  ensure  an  air  gap  is  maintained  at 
hotplate  level.  Tiles  or  other  forms  of  deep 
wall  covering  should  not  obscure  this  gap.  
See Fig.3. 
Overhanging  surfaces  or  a  cooker  hood 
should be a minimum of 685mm above the 
hob.  See Fig.4.  
It is important to ensure that the appliance is 
level  after  installation.  Levelling  feet  are 
fitted  to  the  appliance  to  accommodate 
uneven floors. 
 