Avaya™ ATM WAN Survivable Processor Manager Installation and Configuration
4VITEVMRK7IVZIVWERH;74WJSV
%741EREKIV
Before you can use Avaya™ ATM WAN Spare Processor Manager (ASP Manager) to copy 
translations to WSPs, the following activities must happen. A number of these activities 
require you to call Avaya. To avoid calling repeatedly, read all of the sections first, and then 
determine what activities you need Avaya to perform.
* Note:  We refer to the book, ATM Installation, Upgrades, and Administration Using 
MultiVantage Solutions, 555-233-124, Issue 4, several times in this procedure. This 
book is available from the VisAbility home page, from your ASP Manager 
software CD, or from the Service Centre web site (see 
).
3ZIVZMI[
1.  Install the main server and MultiVantage software, if you have not already.
For instructions on installing main PPNs, visit http://made-easy.avaya.com and click 
the MCC link to view Installation for MCC Made Easy. 
2.  Install the ATM-PNC, if you have not already.
Refer to “Installing a DEFINITY Server ATM-PNC” on page 3-1 in ATM Installation, 
Upgrades, and Administration Using MultiVantage Solutions,
 555-233-124, Issue 4. 
3.  Install the WSPs, if you have not already.
Refer to “Installing a WAN Spare Processor” on page 3-36 in ATM Installation, Upgrades, 
and Administration Using MultiVantage Solutions,
 555-233-124, Issue 4. In addition:
a.  On the WSP, if there are only two carriers installed, make sure that the second 
carrier is a ‘C’ carrier. Chances are the PPN has duplicated SPEs, which makes the 
01B carrier a processor carrier. WSPs have single processors. Once the WSPs have 
a copy of the PPN’s translations loaded and running, SPE dup will be turned off. 
Therefore, in order to make use of the second carrier, it should have the ‘C’ p-plug 
connected to it on the backplane.
b.  If the WSP has 3 carriers, you can either make the second carrier a ‘C’ carrier (as in 
Step 3a, above) or you can leave the second carrier as a ‘B’ carrier, and simply not 
put any circuit packs in it. Instead, place your C-LAN circuit pack in the ‘C’ carrier.