Hoshizaki HWR68A(-D) Manuel D’Utilisation

Page de 64
2. Control Board Layout
Note: Fuse at position F101 on board is not currently used. The board can function 
without this fuse.
SW 135 
Display 
Setpoint
SW 134 
Raise 
Setpoint
SW 133 
Lower 
Setpoint
SW 131 
Energy 
Saving/
Service 
Button
SW 13 
Manual 
Defrost
LED 13 
Lit for 
Negative 
Values
LED 14 
Temperature 
and Alarm 
Display
(brown) Compressor Relay
 (red) Evaporator Fan Relay
 (orange) Defrost Heater Relay
Relay Wiring Harness (K311)
Thermistor Wiring Harness (K151)
Front
K311 (6 pin)
Relay Wiring 
Harness 
K51 (5 pin)
(not used)
K101 (3 pin)
Transformer
K151 (10 pin)
Thermistor 
Wiring 
Harness 
K361 (9 pin)
(not used)
F101 
3 Amp Fuse
(not used)
Relays
(not used)
Chip Revision
Board Part 
Number
Board Part 
Number
Rear
(gray) Clogged Filter Sensor
(orange) Defrost Thermistor
(black) Cabinet Thermistor
(white) Jumper Wire (limits access to settings and    
 
 diagnostics menu - not present on all units)
(light blue) High Pressure Switch