Hoshizaki HWR68A(-D) Manuel D’Utilisation

Page de 64
54
I. Removal and Replacement of Control Board
IMPORTANT
When receiving a service call, please ask the customer to turn the power off, 
then turn it back on and monitor the condition for awhile. Even if the control 
board malfunctions for some reason, it may resume normal operation after the 
power is turned off once.
CAUTION
1. Fragile, handle very carefully.
. The control board contains integrated circuits, which are susceptible to 
failure due to static discharge. It is especially important to touch the metal 
part of the unit when handling or replacing the board.
3. Do not touch the electronic devices on the board or the back of the board to 
prevent damage to the board.
4. Do not attempt to repair the board in the field. Always replace the whole 
board assembly if it goes bad.
5. Do not short out power supply to test for voltage.
6. Keep the thermistor leads, clogged filter sensor leads, and pressure switch 
leads at least 1.5" away from high voltage leads (AC 100 volts or more) to 
protect against electrical noise. 
1) Turn off power and unplug the unit.
) Remove the front panel.
3) Remove the wire guard, then remove all wiring connections at the bottom of the control 
box.
4) Remove the control box by loosening the 4×8 T screw securing the bottom control box 
bracket to the evaporator case cover.
5) Remove the three 4×8 T screws from the control box top and bottom, then carefully 
remove the control box cover.
6) Unhook all wiring connections to the control board.
7) Remove the control board by carefully removing the four 4×8 T attachment screws.
8) Identify the part number and software revision of the new board and make sure it is 
interchangeable with the old board.
9) Install the new board in the control box taking care not to damage it.
10) Hook all wiring connections back to the control board.
11) Check to make sure that the switches and buttons line up appropriately on the display 
panel and that they operate.
1) Replace all panels and guards.
13) Plug in the unit and turn on the power supply.