Hoshizaki HWR68A(-D) Manuel D’Utilisation

Page de 64
57
5. Air Filter
As the air filter becomes clogged with dirt or dust, the unit’s performance will be reduced. 
Do not operate the unit with the air filter removed. This will accelerate clogging of the 
condenser and result in failure. Check the filter at least twice each month. If it is dirty, 
use warm water and a neutral cleaner to wash the filter. To avoid damaging the air filter, 
do not use water hotter than 104°F (40°C). The filter is located behind the front panel. 
This filter can be removed by opening the front panel and lifting the filter away from the 
condenser. Reinstall the filter after cleaning. 
6. Shelves 
Remove and clean regularly.
7. Drawers
On units with drawers, the drawers can be removed for cleaning either individually or as 
an entire assembly.
• To remove an individual drawer, first remove all food product from the drawer. Pull the 
drawer out to its fully extended position and lift up on the handle to disengage the drawer. 
Before removing the drawer, carefully support the rear and front of the drawer and then 
slowly remove it from the cabinet.
• To remove the drawer frame assembly, first remove the drawers and then remove the 
fasteners in the thermal break and in the rear of the cabinet. Carefully slide the frame 
out of the cabinet, making sure not to damage the thermal break. Reinstall in the reverse 
order, making sure not to overtighten the screws in the thermal break.
• To remove the drawer slide (center slide containing rollers) for cleaning, rotate the top 
of the slide away from the frame while the slide is completely inside the cabinet. Drawer 
slides do not require lubrication, but slides should be kept clean and free of food.
Note: Drawer slides are dishwasher safe.
B. Maintenance
1. Air Filter
The air filter promotes clean condenser surfaces and efficient unit operation by removing 
dirt and grease from circulating air. The filter should be checked monthly and cleaned 
when necessary—as described in "A.5. Air Filter".
All other maintenance or service on this unit should be performed in accordance with the
Hoshizaki Service Manual by a qualified service technician.