Frymaster H14 Series Manuel D’Utilisation

Page de 110
 
3–5 
3.  At the programmed shake time, an audible alarm will sound and the display will flash 
SHAKE.  
After shaking the basket, press the corresponding cook switch, 
1
 or 
2
, to cancel the alarm. 
 
0.  After the completing the cooking time, an audible alarm will sound and the display will flash 
pull.  Remove the indicated basket and press the corresponding cook switch, 
1
 or 
2
, to cancel 
the alarm. If no other products are being cooked in the frypot, the display shows
 
7:00 QA 
indicating that the quality timer is counting down.  If the quality time is set for some time other 
than 7:00 minutes, the display starts counting down from that time.  (QA is not available for 
McChicken, Crispy Chicken or Filet-o-Fish). 
 
0.  When the quality time expires, an audible alarm will sound, and the display will flash 
QA
.  Cancel 
the alarm by pressing the corresponding cook switch, 
1
 or 
2
.  
 
 
NOTE:  When you initiate a new cook cycle, the quality time will automatically reset. 
 
 
3.4  M-100B™ Computer Problem Condition Indicators 
 
Open Drain Valve Indication 
 
If, when the ON/OFF 
 switch is pressed to the ON position, the display reads 
IGNITION 
FAILURE, verify that the drain valve is fully closed.  A drain safety switch built into the drain valve 
assembly prevents the elements from being energized if the valve is not completely closed.  After 
verifying that the valve is fully closed, turn the computer OFF* for at least 5 seconds, then turn it back 
on.  If the message reappears, there is a problem in the electrical circuitry of the fryer or the computer; 
contact your Frymaster Factory Authorized Service Center (FASC). 
 
* On early-version M-100B split-vat units, BOTH computers must be turned off, even though the 
problem condition may be associated with only one vat. 
 
Low Temperature Indication 
 
If the frypot temperature drops to more than 45
°F (25°C) below the programmed setpoint temperature 
during the cooking cycle, the cook switches will lock, the display will flash
 
lOW TEMP  and an 
audible alarm will sound. If the frypot temperature returns to a range between 45
°F (25°C) to 15°F 
(8
°C) of setpoint, the audible alarm will stop, but the cook switches remain locked and the display 
alarm continues flashing.  All functions return when the frypot temperature is within 15
°F  (8°C) of 
the programmed setpoint. 
 
Probe Failure Indication 
 
If the temperature probe fails, the display will flash 
PROBE FAILURE and an audible alarm will 
sound.  To cancel the alarm, turn the computer OFF.  In split-vat fryers, turn off the side in which the 
failure occurred.  If a probe fails during the high-limit test, 
PROBE FAILURE is displayed. 
 
NOTE:  If the temperature probe fails in the left side of a split-vat, that side cannot be turned back 
ON once it has been turned OFF.