Frymaster H14 Series Manuel D’Utilisation

Page de 110
2–2
2.2
After Fryers Are Under The Fry Station Hood
Adjust casters so that fryers are level and at the proper height in the fry station hood.  If necessary,
level the fryer(s) by loosening the locking screw on the caster leg and screwing the caster in or out.
When fryer is level and at proper height, retighten the locking screw on the caster leg.
Secure the fryer in place under the hood with the restraining hardware installed with the hood.
2.3
Power Requirements
 
DANGER
Copper wire suitable for at least 167°F (75°C) 
MUST
MUST
MUST
MUST be used for power connections.
MODEL
VOLTAGE
PHASE
WIRE
SERVICE
MIN.
SIZE
AWG
(mm2)
AMPS PER LEG
     L1          L2          L3
H14
208
3
3
6
(16)
39
39
39
H14
240
3
3
6
(16)
34
34
34
H14
480
3
3
8
(10)
17
17
17
H14
220/380
3
4
6
(16)
21
21
21
H14
240/415
3
4
6
(16)
20
20
21
H14
230/400
3
4
6
(16)
21
21
21
ALL
208
3
3
6
(16)
39
39
39
14 SERIES
240
3
3
6
(16)
34
34
34
EPRI
220/380
3
4
6
(16)
21
21
21
UNITS
240/415
3
4
6
(16)
20
20
20
 
DANGER
The electrical power supply for this appliance 
MUST
MUST
MUST
MUST be the same as indicated on
the rating and serial number plate located on the inside of the fryer door.
 
DANGER
This appliance 
MUST
MUST
MUST
MUST be connected to the voltage and phase as specified on the
rating and serial-number plate located on the inside of the fryer door.
 
DANGER
All wiring connections for this appliance 
MUST
MUST
MUST
MUST be made in accordance with the
wiring diagrams furnished with the equipment.  Wiring diagrams are located on the
inside of the fryer door.