Note 
If an alarm occurs during periodic logout/login at an external alarm 
input, or if a periodic alive SMS is due, the device will immediately 
re-login by itself. If the logout time has not expired yet, the device 
logs out again afterwards. 
If a data connection exists, the device will postpone the logout pro-
cedure. A voice connection and a communication in AT command 
mode will interrupt the device immediately when logging out. 
Scheduled logout and login 
It is useful to log the device out for a short period and log in again every day to allow 
maintenance functions of the GSM provider. Enter the logout time and the duration (1 to 
98 minutes).  
Subsequently, the device logs in into the GSM network again, provided the PIN of the SIM 
card is stored. 
Periodical logout/login with reset 
In addition, the device can perform a device reset during logout/login using Periodical 
logout with reset.  
After the device reset, the device logs in into the GSM network again, provided the PIN of 
the SIM card is stored. 
Periodic alive message via SMS 
The device can send a periodic alive message to the entered phone number as SMS mes-
sage daily, weekly or monthly. The LED Status is flashing during the dispatch. (see 
Chap. 6.2.6 ) 
Power up SMS 
If this function is enabled, the device will send an SMS every time the power is inter-
rupted for at least five seconds (not reset) (see Chap. 6.2.6). 
The device will add the date and the time to the power up SMS. The date and the time 
will have a maximum accuracy of five minutes. 
The LED Status is flashing during the dispatch. 
 Configure system monitoring 
1. 
Start the program HSComm under Windows. 
The configuration software is started and displays the tab "Basic settings".  
2. 
To enable scheduled login/logout, activate one of the check boxes "Periodical log-
out with reset" or "Periodical logout" in the group "System monitoring" and enter 
the requested values in the entry fields "Time" or "Duration". 
 
 
Note 
Enter the phone numbers in international format, e.g. Germany: 
+49... 
3. 
To activate the periodic alive message via SMS, enter the requested values in the 
fields "Phone number", "Text" and "Time" in the group "System monitoring".  
To enable the power up SMS, activate the check box "Power up SMS" in the group 
"System monitoring" and enter the requested values in the fields "Target" and 