Configure selective call acceptance
1.
In the tab "Access control" in the group "Selective call acceptance", activate the
control box "Only accept calls from these numbers".
control box "Only accept calls from these numbers".
2.
Enter the requested numbers in the entry fields.
3.
Perform a reset. (see Chap. 2.7.2 )
Pertinent AT commands
AT**CLIP
Selective Call Answer
AT**RESET
Device reset
Non-authorized numbers
The device will reject calls from non-authorized numbers immediately to keep the line
free. These calls can also not be accepted manually (ATA). The caller receives the signal
BUSY.
The device will reject calls from non-authorized numbers immediately to keep the line
free. These calls can also not be accepted manually (ATA). The caller receives the signal
BUSY.
The GMS engine will then work with the setting AT+CLIP=1. For each incoming call, the
following phone number is displayed as well:
Ring
+CLIP: „+49941560061“,145,,,,0
following phone number is displayed as well:
Ring
+CLIP: „+49941560061“,145,,,,0
6.3.9 Passwords and DTMF PIN
Besides the PIN for the SIM card (see Chap. 6.1.1), which controls the access to the GSM
network, the device manages three other passwords/PINs to control the access to the
following:
network, the device manages three other passwords/PINs to control the access to the
following:
Data connection, security callback
Remote configuration, control by SMS
Remote configuration, control by SMS
The password consists of a maximum of 16 characters.
Data connection, security callback
This password controls
This password controls
Incoming data connections
Triggering the security callback (see Chap. 6.3.10)
Triggering the security callback (see Chap. 6.3.10)
When an incoming connection is accepted and established, the caller is asked to enter
the password after 2 seconds:
If no valid password is entered within 60 seconds, the device will terminate the connec-
tion. A valid password is acknowledged with OK.
If no security callback number is entered (see Chap. 6.3.10), the connection is free for
data transmission after 2 seconds.
the password after 2 seconds:
If no valid password is entered within 60 seconds, the device will terminate the connec-
tion. A valid password is acknowledged with OK.
If no security callback number is entered (see Chap. 6.3.10), the connection is free for
data transmission after 2 seconds.
Remote configuration, switching via SMS
This password controls
This password controls
Switching to remote configuration via data connection
Accepting SMS messages to switch and query the inputs/outputs
Accepting SMS messages to switch and query the inputs/outputs
(see Chap. 6.2.2)
Accepting SMS messages with extended AT** commands (see Chap. 6.2.4)
During a data connection, you can switch to remote configuration mode by entering the
escape sequence (default setting ***). (see Chap. 4.1)
escape sequence (default setting ***). (see Chap. 4.1)