INSTALLATION
ERROR CODES
When the oven malfunctions, an error code will appear in the display.
 
 PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.
The icons that begin to flash represent operational modes that are still usable.
When the oven fault is corrected, the Combitherm will return to normal operation.
Error 
Code
Display Shows
Model
Mode
ES
ESG
ESI
Steam
Combination
Convection
Retherm
E01 
Low Water Boiler 
Yes 
No 
No 
No 
To 365°F 
No
E02 
Control Temp High 
Yes 
Yes 
No 
No 
No 
No
E03 
Fan Motor Error 
Yes 
Yes 
No 
No 
No 
No
E04 
Fan Motor 2 Error 
Yes 
Yes 
No 
No 
No 
No
E11 
Convection Temperature High 
Yes 
Yes 
BOILER UNITS 
ONLY
No 
No 
No
E13 
Boiler Temperature High 
Yes 
No 
No 
No 
Yes 
No
E15 
Condenser Temperature High 
Yes 
Yes 
No 
No 
To 356°F 
No
E20 
B11 Core Temperature Probe Single Point 
Fault - HACCP only
Yes 
Yes 
No 
No 
No 
No
E21 
N6 Cavity Probe Fault 
Yes 
Yes 
BOILER UNITS 
ONLY
No 
No 
No
E22 
B10 Core Temp Probe Fault 
Yes 
Yes 
BY TIME ONLY 
BY TIME ONLY 
BY TIME ONLY 
BY TIME ONLY
E23 
B4 Boiler Probe Fault 
Yes 
No 
No 
No 
No 
No
E24 
B5 Bypass Probe Fault 
Yes 
Yes 
No 
No 
Yes 
No
E25 
B3 Condenser Probe Fault 
Yes 
Yes 
Yes 
No 
To 356°F 
No
E26 
N8 Boiler Safety Temperature Probe Fault 
Yes 
No 
No 
No 
No 
No
E27 
Boiler Element Temperature High 
Yes 
No 
No 
No 
Yes
No
E34 
Steam Generator Drain Pump Fault 
Yes 
No 
No 
No 
No 
No
E36 
Steam Temperature High 
Yes 
No 
No 
No 
Yes 
No
E51 
No Water in Boiler 
Yes 
No 
No 
No 
Yes 
No
E53 
Fan Motor High Temperature 
Yes 
Yes 
No 
No 
No 
No
E54 
Fan Motor 2 High Temperature 
Yes 
Yes 
No 
No 
No 
No
E55 
Vent Not Open 
Yes 
Yes 
Yes 
(
NO BROWNING
)
Yes 
(
NO BROWNING
)
Yes 
(
NO BROWNING
)
Yes 
(
NO BROWNING
)
E57 
No Rinse Water 
Yes 
Yes 
Yes 
Yes 
Yes 
Yes
E93 
Communication Error FROM Display Board  Yes 
Yes 
No 
No 
No 
No
E94 
Communication Error TO Display Board 
Yes 
Yes 
No 
No 
No 
No