Scag Power Equipment SFZ36-20BS Manuel D’Utilisation

Page de 69
32
R
Section 7
 WARNING
Electric  storage  battery  fluid  contains  sulfuric 
acid  which  is  POISON  and  can  cause  SEvERE 
CHEMICAL  BURNS.  Avoid  contact  of  fluid  with 
eyes, skin, or clothing. Use proper protective gear 
when handling batteries. DO NOT tip any battery 
beyond 45° angle in any direction. If fluid contact 
does occur, follow first aid suggestions below.
BATTERY ELECTROLYTE FIRST AID
External Contact — Flush with water.
Eyes — Flush with water for at least 15 minutes 
and get medical attention immediately.
Internal — Drink large quantities of water. Follow 
with Milk Of Magnesia, beaten egg, or vegetable 
oil. Get medical attention immediately. In case of 
internal contact, DO NOT give fluids that would 
induce vomiting.
A. CHARGING THE BATTERY
Refer  to  the  battery  charger’s  manual  for  specific 
instructions.
Under normal conditions the engine’s alternator will have 
no problem keeping a charge on the battery. If the battery 
has been completely discharged for a long period of time, 
the alternator may not be able to recharge the battery, and 
a battery charger will be required.
DO NOT charge a frozen battery. It may explode and cause 
injury. Let the battery warm before attaching a charger.
Whenever  possible,  remove  the  battery  from  the  mower 
before charging and make sure the electrolyte covers the 
plates in all cells.
 WARNING
BATTERIES  PRODUCE  EXPLOSIvE  GASES. 
Charge the battery in a well ventilated space so 
gases produced while charging can dissipate. 
Charging rates between 3 and 50 amperes are satisfactory 
if  excessive  gassing  or  spewing  of  electrolyte  does  not 
occur  or  the  battery  does  not  feel  excessively  hot  (over 
125°F). If spewing or gassing occurs or the temperature 
exceeds  125°F,  the  charging  rate  must  be  reduced  or 
temporarily stopped to permit cooling.
B. JUMP STARTING
The booster battery must be a 12 volt type. If a 
1. 
vehicle is used for jump starting, it must have a 
negative ground system.
When connecting the jumper cables, connect the 
2. 
positive cable to the positive battery post, then 
connect the negative cable to the negative battery 
post.
DRIvE BELTS
7.7 
All  drive  belts  are  spring-loaded  and  self-tensioning, 
however after the first 2, 4, 8 and 10 hours of operation, 
the belts should be checked for proper alignment and wear. 
Thereafter, check the belts after every 40 hours of operation 
or weekly, whichever occurs first.
- Note -
If you experience frequent belt wear or breakage, 
see your authorized Scag service center for belt 
adjustment.