Zephyr AK8200AS Manuel D’Utilisation

Page de 22
12
www.zephyronline.com
Installation – 
Remote Blower Preparation
1.  Place 8” round adapter on top of power pack 
and secure with (4) M4x8 screws. Connect 8” 
round duct work to 8” round adapter.
2.  Install threaded end of remote blower wiring 
through external blower wiring knock out (B)
located in junction box on top of power pack.
3.  Place cap over threaded end of remote blower 
wiring and secure by turning clockwise. 
4.  Connect 6 pin male connector from blower 
wiring to 6 pin female connector in the power 
pack. (plug is located inside the power pack 
protruding from the white control board box). 
NOTE: For instructions on installing remote blowers, please refer to the CBE-1000 or PBN-1000A 
manuals included in the blower packaging and on our website: www.zephyronline.com
 
    CBE-1000 / PBN-1000A: WIRING DIAGRAM
White (common)
Black (high)
Blue (med)
Red (low)
Green (ground)
Remote Blower
Wiring Box
(hood)
Junction Box
(Remote Blower)
B
B
A
A: Ground wire screw 
location (inside)
5.   Secure green ground wire from remote
      blower wiring to ground screw located
      inside the power pack