Restart Continuous Trigger mode. RCT.  
The RCT mode makes it possible to use a lens with video controlled iris for intelligent traffic 
surveillance applications, ITS. The camera is running continuously, and the iris is controlled from 
the iris video output. When a trigger pulse is applied, the scanning is reset, the previous signal is 
dumped with a fast dump read out, and the new triggered exposure is started. This fast dump 
read out takes 133 H (5,23 msec. and it has the same effect as “smearless read out”. Smear over 
highlighted areas are reduced for the triggered frame. In edge pre-select mode (TR=1), the RCT 
mode (RC=1) can be activated. RCT cannot be selected by switch settings. 
Trigger
SG
Exposure
Video out
Dump
Read out
Continuous video out
Continuous video out
Triggered
Frame
Trigger
SG
Exposure
Video out
Dump
Read out
Continuous video out
Continuous video out
Triggered
Frame
Fig. 15. Restart Continuous Trigger mode. 
 
Trigger modes with possible functions
 
Scanning 
Full scanning 
Partial scanning 
 
TR= 
*) Binning  norm.  v 
 
 
norm 
 
 
 
Remarks 
Normal 
√ 
√ 
 
 
√ 
n    
SH= , PE=  for shutter select 
Edge Pre-
select 
√ 
√ 
 
 
√ 
n    
SH= , PE=  for shutter select 
SL= , Smearless active 
RC=1 for Restart Continuous Trigger mode 
Pulse Width 
√ 
√ 
 
 
√ 
n    
SL= , Smearless active 
Fr. Delay 
read out 
√ 
√ 
 
 
√ 
n    
SH= , PE=  for shutter select 
ML= , Multi shutter active 
SL= , Smearless active 
*) Binning will only work  
 
√  Allowed and described mode  
   for CV-M4
+
 and CV-M4CL
+
 
 
n  Non-allowed.  
 
All trigger modes can be H synchronous or H a-synchronous. (HC=0, HC=1)  
In Edge Pre-select mode (TR=1), the Restart Continuous Trigger mode can be activated 
(RC=1) by RS-232C and CL only. 
 
6.2. Output of Timing Signals  
It is not possible to synchronize the camera from an external sync source except by extern 
trigger. The camera will always run with its internal X-tal controlled timing.  
 
The CV-M4
+
 camera is designed for easy interfacing to frame grabbers with LVDS signal levels 
(EIA64), or with Camera Link interface. 
To synchronize the video data transfer from the camera the following signals are available: 
 FEN 
Frame 
enable 
 LEN 
Line 
enable 
 PCLK 
Pixel 
clock 
 DVAL 
 
 
EEN 
Exposure enable. (Low during active exposure). 
See the full connector pin assignment for LVDS a Camera Link in chapter 5.2 and 5.3.  