6
Initializes the PIRQx (PCI Interrupts) route control registers in the 
IBC (PCI/ISA bus bridge controller). The ENV parameter is a 32-bit 
value that is divided by 4 to yield the values for route control registers 
PIRQ0/1/2/3. The default is determined by system type. For details on 
PCI/ISA interrupt assignments and for suggested values to enter for 
this parameter, refer to the 8259 Interrupts section of Chapter 5 in the 
MVME2400-Series VME Processor Module Programmer’s Reference 
Guide
.
Note
LED/Serial Startup Diagnostic Codes: these codes can be 
displayed at key points in the initialization of the hardware 
devices. Should the debugger fail to come up to a prompt, the 
last code displayed will indicate how far the initialization 
sequence had progressed before stalling. The codes are 
enabled by an ENV parameter:
Serial Startup Code Master Enable [Y/N]=N?
A line feed can be inserted after each code is displayed to prevent it 
from being overwritten by the next code. This is also enabled by an 
ENV parameter:
Serial Startup Code LF Enable [Y/N]=N?
The list of LED/serial codes is included in the section on MPU, 
Hardware, and Firmware Initialization
 in Chapter 1 of the PPCBug 
Firmware Package User’s Manual
.
Configuring the VMEbus Interface
ENV asks the following series of questions to set up the VMEbus interface 
for the MVME240x modules. To perform this configuration, you should 
have a working knowledge of the Universe ASIC as described in your 
MVME2400-Series VME Processor Module Programmer’s Reference 
Guide
.
VME3PCI Master Master Enable [Y/N] = Y? 
Y
Set up and enable the VMEbus Interface. (Default)
N
Do not set up or enable the VMEbus Interface.