Magnetek Quattro DC Elevator Drive Manuel D’Utilisation
Quattro DC Multistep Ref A3 Submenu
Parameter Description
Units
Default
Range
Hidden
Item
Run
lockout
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 1
Multi-step speed
command #1
command #1
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 2
Multi-step speed
command #2
command #2
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 3
Multi-step speed
command #3
command #3
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 4
Multi-step speed
command #4
command #4
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 5
Multi-step speed
command #5
command #5
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 6
Multi-step speed
command #6
command #6
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 7
Multi-step speed
command #7
command #7
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 8
Multi-step speed
command #8
command #8
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 9
Multi-step speed
command #9
command #9
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 10
Multi-step speed
command #10
command #10
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 11
Multi-step speed
command #11
command #11
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 12
Multi-step speed
command #12
command #12
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 13
Multi-step speed
command #13
command #13
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 14
Multi-step speed
command #14
command #14
m/sec
0.000
-16.000 – +16.000
N Y
ft/min 0.0 -3000.0 – +3000.0
SPEED COMMAND 15
Multi-step speed
command #15
command #15
m/sec
0.000
-16.000 – +16.000
N Y
Table 6: Multi-Step Ref A3 Submenu
42