Bunn EQHP-10L Fascicule

Page de 2
BUNN
®
 practices continuous product research and improvement. We reserve the right to change specifications and product design without notice. Such 
revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
All dimensions shown in inches. 
 
Bunn Corporation owns all copyrights relating to materials in this publication.  Please contact Bunn Corporation to request permission to reproduce any portion of this publication. 
Dimensions & Specifications
BUNN Corporation - 1400 Stevenson Drive Springfield, Illinois 62703 • 800-637-8606 • 217-529-6601 • Fax 217-529-6644 • www.bunn.com
Note:  Inlet and outlet plumbing connections are 3/8” FNPT.
Do not use with water that is microbiologically unsafe or of unknown quality 
without adequate disinfection before or after the system. Systems certified for 
cyst reduction may be used on disinfected water that may contain filterable 
cysts. EPA Establishment Number 070595-CT-001.
BUNN recommends regularly scheduled maintenance and replacement of 
the filter cartridge(s) in order for the product to perform as advertised/sold. 
Change the filter cartridge at least every 6 months. BUNN shall not be liable 
for system failures due to improper maintenance.
*16oz. drinks with location operating 365 days/year. 
Assumption includes no ice in beverage.
EQHP-10L or EQHP-10
Model
Product #
Service Flow 
Rate & Capacity
Micron 
Rating
Bunn Applications
Other Applications
Medium to High Volume
 
39000.0001 EQHP-10L 1.5 gpm/10,000 
Gallons
1.0
CWT(F), CDBC(F), AXIOM Series, Infusion 
Series, Liquid Coffee, TB3(Q), TU5Q, iMIX, 
Dual, Dual TF, Dual SH, LCR-2, LCA-2, Urns, 
3-Gallon Systems, HW2, H5E/X, H10X. 
 
For Example (6 month period): 
195 Cups of Coffee, 80 Glasses of
Ice Tea and 160 Cups of Cappucino per day* 
 
Combinations totalling 10,000 gallon usage 
per 6 months. 
ICE MAKERS: 
Cubers to 750lbs. 
Flakers to 1200lbs. 
 
Summary, for use in medium/high volume 
applications where 
scale inhibitor is needed.  
39000.0004 EQHP-10 1.5 gpm/10,000 
Gallons
1.0
TCD-1/2, LCA-2 IC, Granita Auto-Fill Systems. 
 
In hard water situations combine with 
Scale-PRO to reduce scale build up in hot 
beverage and ice applications.
Single Low Flow Carbonater:  80,000 16oz 
Soft Drinks before change out. 
(437 Drinks per day)*. 
 
Summary, for use in medium volume 
applications where scale inhibitor is not 
needed.  Any beverage or application using 
ambient water.