Samsung RS2544 Manuel D’Utilisation

Page de 66
4. Specifications
Defrost Control                    From 24 to 32 hrs
Thermo-Bimetal            54
(off)/23
(on)  
Defrost Thermistor(502AT)                 50
(off) 
Electrical Rating           AC115V 60Hz, 4.8 Amps
Maximum Current Leakage
0.25 mA
Maximum Ground Path Resistance  0.1 Ohm
Energy Consumption               KWH/mo.
Ambient Temperature 
70
90
Refrigerator,
34
46    34
46
Freezer,
-14
8     -14
8
Run Time,%                               40           60  
Refrigerant Charge (R134a)
7.76 oz
Compressor(MK183C-L2U)
532.3 Btu/hr
Compressor oil                                     Freol 
α
-15
Capillary tube(Dia, Length)                 0.033
,130
Dryer                                      Molecular Sieve XH-9
Clearance must be provided for air circulation
AT  TOP                                                                      1
AT SIDES                           0.1
AT REAR                              1
RS2544, RS2622, RS2644, RS2666, RS2777
Main Board(RS2622)                   DA41-00134A
Main Board(RS2544/2644/2666)    DA41-00104L
Main Board(RS2777)               DA41-00104E
Thermistor(Freezer)                       DA32-10109W
Thermistor(Freezer Evaporator)     DA32-00006A
Thermistor(Refrigerator)             DA32-10105U
Thermistor(Refrigerator Evaporator) DA32-00006B
Thermistor(Ambient)                  DA32-10109V
Thermistor(CoolSelect Zone
TM
)            DA32-10109X
Thermistor(Ice-Maker)               DA32-10108B
Thermo-Bimetal    
DA47-10160E
Relay                                   DA35-10013Q
Overload Relay                         DA34-10003D
Run Capacitor (12
)                    2501-001045
Fan-Motor(FRE)                    DA31-00020E
Fan-Motor(REF)      
DA31-00002S(RS2622)
Fan-Motor(REF)
DA31-00020E(RS2544/2644/2666/2777)
Fan-Motor(Condenser)  
DA31-00020H
Thermal Fuse         
DA47-00095C
Fan
Fan
Fan
Fan
Fan
Fan
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
Heat exchanger
Heat exchanger
Heat exchanger
Heat exchanger
Compressor
Dryer
C-Fan
Electric box
Sub-condenser
ELECTRICAL SPECIFICATIONS
Freezer 
Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
MODELS
REPLACEMENT PARTS