Samsung RS2622 Manuel D’Utilisation

Page de 66
46
Check the exchange of fuse and
disconnection cause.
- Check the connections of main PCB.
- Check the connections between upper
hinge and CABI-door.
- Check the connections between door and
panel PCB.
11. Diagnostics
11-1) If power is not ON
At the power of main PCB, the 115V power and a high-voltage over DC
170V occur. Please take care of yourself on repair and measurement.
Is 115V AC fuse down?
Is power 115V  
both terminals of CN10?
Is fuse on main PCB down?
Is DC 170V impressed to both 
terminals of BD1?
Top S/W 233Y
Is the voltage impressed DC 5.8V 
between C and S ?
Is 12V impressed to both 
terminals of C102?
Is the load such as relay normal?
Is  normal the load, such as 
relay?
Is there any PCB soldering, short or broken?
Normal
Start
To check the main PCB, please apply
descriptions of operation and
references in the manual.
YES
Check the assembly and connection of
electric wires.
NO
Exchange fuse
115V 2A?
YES
Check the PCB pattern and replace BD1.
NO
Replace PCB assembly.
NO
1) Replace D104 (D5S6M).
2) Replace PCB assembly.
NO
Replace REG1(KA7805)
NO
1) Check the assembly of electric wires and troubleshoot.
2) Replace the panel PCB.
NO
1) Replace the corresponding relay.
2) Check lead wire for contact.
NO
Caution!