2) Water Supply Function
2-1) After finishing the ice extraction operation (initial ice extraction operation, normal ice extraction operation and  ice
extraction operation of test function) and performing the ice receptacle horizontality operation, if it is judged to
have attained horizontality, then there is executed operation of water solenoid located in refrigerator machine
compartment for time check function so as to supply water into the ice maker receptacle.
3) Ice-Making Function
Here is referred to period until it is opined that water in ICE -TRAY(ice maker vessel) has completely become ice
after finishing the water supply operation, which period is judged by sensed temperature (which is alterable option)
of ice maker sensor.
3-1) The ice maker sensor temperature is automatically checked after 58 minutes have elapsed (65 minutes in case of
overload) from the time when water was supplied into the ice maker receptacle.
3-2) If the ice maker sensor maintains below  stays 1.4 for 5 minutes, then it is judged that the ice making cycle has
been completed.
3-3) In case of initial electric power application to the product or in case of recovery from a power outage, the ice
extraction is operated after waiting 2 hours, not detaching the ice after checking the the ice maker sensor even
though the temperature may be checked to have reached below 1.4
4) Ice Extraction Function
The ice extraction function is to separate the ice in the ice extraction (ice maker vessel) after
completing the ice making process. This function is achieved by operating in accordance with to the
following steps. These operations are classified into full ice case and non-full ice case according to the
ice extraction S/W condition variation:
4-1) Step 1: this is stage to check firstly the ice making temperature in order to perform ice extraction where check is
performed both if the current ice making temerature is below 1.4 and if 90 minutes (55minutes in case
of power freezing) have elapsed after water supply.
- If the F compartment enters defrosting while waiting for ice tray, counting is restarted from 0 after defrosting is
completed so that the check is performed if the ice extraction waiting (58 minutes) has elapsed after defrosting
the F compartment. The ice maker temperature sensor enters step 2 if 5 minutes pass after going below 1.4 .
Model
Water Supply Time
Cf. OPTION function &
FLOW_SENSOR function
It may be altered by OPTION function and water supply rate may vary
depending on water pressure since it is connected directly to the
water source.
Model furnished with
ice-maker function
option
Remark
Note) While it is not full of ice is not fully frozen or when ICE OFF has not been selected, it operates
internally at -13. until it becomes full of ice (until the ice tray is of ice). As soon as full ice is
achieved, the freezer compartment temperature is automatically controlled at the temperature set
by the customer.
Full ice case : step 1 
step 2
step 3 
step 4
step 5
step 6
Non-full ice case : step 1 
step 2 
step 6 
19