Samsung RM255BABB Manuel D’Utilisation

Page de 88
OPERATING INSTRUCTIONS & INSTALLATION
No
ITEM
F-DEF-SENSOR
F-FAN ERROR
C-FAN ERROR
CF-SENSOR
CF-FAN ERROR
CR-FAN ERROR
-
TROUBLE
REMARK
16
17
18
19
20
21
22
23
24
25
26
27
ICE PIPE
HEATER ERROR
Uart
COMMUNICATI
ON ERROR
L
M COMMUNICATI
ON ERROR
P
M COMMUNICATI
ON ERROR
F-DEFROSTING
ERROR
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
nor higher than -58
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant
fan motor.
Error is displayed in case there is contact failure on the feedback signal line,
motor wire missing or defect of the motor itself when operating the relevant
fan motor.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when sensor
detection temperature is not lower than 122 nor higher than -58
Error occurs and is displayed when regarding the F compartment defrosting heater, there is a electric wire
cut, short-circuit, contact failure, of sensor housing missing, or defective temperature fuse. A defect is
displayed if defrosting is not finished after continuous heating for more than 80 min, for the F compartment.
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant fan
motor.
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant fan
motor.
Error is displayed in case of ice pipe heater housing missing or
electric wire cut.
Communication error with the electric power cord MODEM
Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound
if communication between MICOM MAIN    LOAD is not achieved due to an
interruption of more than 10 seconds.
Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound
if communication between MICOM MAIN    PANEL is not achieved due to an
interruption of more than 10 seconds.
30