Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
STATus Subsystem
TVS600 & TVS600A Command Reference
2–157
STATus:OPERation?
STATus:OPERation:CONDition?
STATus:OPERation:PTRansition
STATus:PRESet
STATus:OPERation:PTRansition
STATus:OPERation:PTRansition?
Sets or queries the contents of the Operation Positive Transition Register
(OPTR). When you set an event bit true (1) in the OPTR, the OPTR reports an
event in the Operation Status Register when the Operation Status Condition
Register event line changes from false to true (0 to 1)
The query returns the
current setting as a decimal number whose bits correspond to the Operation
Status Register bits. Refer to Table 2–2 on page 2–152 for a definition of the
events associated with the Operation Status Register bits. The command
STATus:OPERation:NTRansition provides similar control for negative event
transitions. For an overview of the status and event reporting system, refer to the
TVS600 & TVS600A Series Waveform Analyzers User Manual.
STATus:PRESet sets all register bits to one (1) which enables reporting positive
event transitions. Setting unused enable bits does not generate an error, they are
ignored.
STATus:OPERation:PTRansition <mask>
STATus:OPERation:PTRansition?
<mask>
Query response
<NRf > | <Non-decimal numeric>
 N 
 #HFFFF
<NR1>
Not applicable
Execution Error –222, “Data out of range”
Attempted to set the transition register to an illegal value.
None
Command:
STAT:OPER:PTR #H0010
With this parameter value, (decimal 16), the Operation Positive
Transition Register sets only the Acquiring/Measuring event bit
Related Commands
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples