Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
STATus Subsystem
2–164
TVS600 & TVS600A Command Reference
STATus:QUEStionable:ENABle
STATus:QUEStionable:ENABle?
Sets or queries the contents of the Questionable Status Enable Register (QSER).
The QSER allows you to individually disable any of the Questionable events
from setting bit 3 in the Status Byte Register. The query returns the current
setting as a decimal number whose bits correspond to the Questionable Status
Register bits. Refer to Table 2–3 on page 2–162 for a definition of the events
associated with the Questionable Status Register bits. For an overview of the
status and event reporting system, refer to the TVS600 & TVS600A Series
Waveform Analyzers User Manual
.
STATus:PRESet sets all register bits to zero (0) which disables all Questionable
events. Setting unused enable bits does not generate an error, they are ignored.
STATus:QUEStionable:ENABle <mask>
STATus:QUEStionable:ENABle?
<mask>
Query response
<NRf > | <Non-decimal numeric>
 N 
 #HFFFF
<NR1>
Not applicable
Execution Error –222, “Data out of range”
Attempted to set the enable register to an illegal value.
None
Command:
STAT:QUES:ENAB #H0001
Query:
STAT:QUES:ENAB?
Response:
1
STATus:PRESet
STATus:QUEStionable?
STATus:QUEStionable:CONDition?
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands