Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
TRIGger[:A] Subsystem
2–238
TVS600 & TVS600A Command Reference
TRIGger:HOLDoff:TIME
TRIGger:HOLDoff:TIME?
Sets or queries the trigger holdoff time. Trigger holdoff determines how long
after one trigger event the event detector will ignore valid triggers. You can use
holdoff to trigger at a particular point in a recurring sequence of pulses.
TRIGger[:A]:HOLDoff:TIME <holdoff_time>
TRIGger[:A]:HOLDoff:TIME?
<holdoff_time>
1
Query response
<NRf >
250 ns 
 N 
 12 s  (in 8 ns steps)
MINimum
MAXimum
<NR3>
250.0E–9
12.0E+0
1
The default for the parameter <holdoff_time> is seconds (S). You can also use the
multipliers MS for milliseconds, US for microseconds, and NS for nanoseconds.
250.0E–9
Execution Error –222, “Data out of range”
Attempted to set holdoff time to an illegal value.
None
Command:
TRIG:HOLD:TIME 10E-6
Query:
TRIG:HOLD:TIME?
Response:
10.0E-6
None
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands