Tektronix TVS600 & TVS600A Series Manuel D’Utilisation

Page de 410
TVS600 & TVS600A Command Reference
2–13
AVERage Subsystem
This section describes the commands in the [SENSe:]AVERage subsystem. See
Figure 2–5. These commands select and setup one of four acquisition modes:
normal, average, envelope, and peak detect. (Peak detect is available for
TVS600A models only.) All active channels are affected by the acquisition mode
selected. Averaging, peak detecting, and enveloping occur in the acquisition
system before waveform records are passed to the CALC blocks. See Figure 2–6.
AVERage
[SENSe:]
[:STATe]
:COUNt
:TYPE
Figure 2–5: AVERage subsystem hierarchy
:SWEep
:DETector
:ROSCillator
INPut[1]
SENSe
:VOLTage[1]
INPut2
:FUNCtion
:DATA
:VOLTage2
:AVERage
CH 1
CH 2
:AADVance
Figure 2–6: AVERage subsystem functional model