Troubleshooting
With proper installation, operation and maintenance your gas stove will provide years of trouble-free service. If you do 
experience a problem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the 
corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician.
Electronic Ignition System
Symptom
Possible Causes
Corrective Actions
1.
No transmission, motor does 
not turn.
A.
Receiver must learn new 
code.
Press and hold the receiver’s reset button until you hear 2 acoustic signals. 
After the second longer acoustic signal, release the reset button and within the 
subsequent 20 seconds, press the down arrow on the remote handset until you 
hear an additional long acoustic signal confi rming the new code is set.
2.
No ignition. No tone.
A.
Receiver
Replace receiver and reprogram code.
3.
No ignition; one 5 seconds 
continuous tone (7 shorts 
beeps might be heard prior to 
the 5 seconds tone).
A.
ON/OFF switch is in OFF 
position.
Push switch to ON position.
B.
Loose wire.
Secure wire.
C.
Receiver.
Replace receiver and reprogram.
D.
Bent pins on 8 wire 
connector.
Straighten pins on 8 wire connector.
E.
Valve.
Replace valve.
4.
No pilot fl ame and control 
continues to spark.
A.
Air in the pilot supply line.
Purge the line or start ignition several times.
B.
Thermocouple circuit 
wired incorrectly.
Check polarity of the thermocouple wires.
C.
No spark at pilot burner.
Check spark gap, check wiring connection. Check for spark in location along 
cable.
D.
Valve.
Replace valve. Do not over tighten.
E.
Over tightened 
thermocouple interrupter.
Replace valve and thermocouple interrupter.
F.
Receiver.
Replace receiver and reprogram code.
5.
Pilot is lit and control 
continues to spark. Valve 
shuts off after 10...30 
seconds. Valve operates 
manually.
A.
Receiver.
Replace receiver and reprogram code.
6.
Pilot is lit, sparking stops if a 
fl ame is present. Valve shuts 
off after 10...60 seconds. 
Valve does not work manually.
A.
Thermocouple.
Replace thermocouple.
B.
Low inlet pressure to 
valve.
Confi rm suffi cient inlet pressure to the valve. Adjust or replace inlet regulator if 
necessary.
C.
Valve.
Replace valve. Do not tighten the thermocouple interrupter.
7.
3 short beeps while the motor 
turns.
A.
Batteries are low.
Replace batteries - quality alkaline recommended. WARNING: Creating an 
electrical short between the batteries/battery box and metal parts of the appliance 
may render the receiver inoperable.
8.
Pilot fl ame lights but there is 
no main gas fl ow.
A.
Manual override know 
(if equipped) is in MAN 
position.
Turn Manual override know to ON position.
B.
Valve turned don to pilot 
fl ow.
Turn fl ame to high fi re by pressing up button on remote handset.
C.
Low inlet pressure to 
valve.
Confi rm suffi cient inlet pressure to the valve. Adjust or replace inlet regulator if 
necessary.
D.
Valve.
Replace valve.
9.
Pilot sparks, but pilot will not 
light.
A.
Correct gas supply.
Verify that incoming gas line ball valve is “open”. Verify that inlet pressure reading 
is within acceptable limits, inlet pressure must not exceed 50 mbar.
B.
Ignitor gap is too large.
Verify that spark gap from ignitor to pilot hood is .43 cm.
C.
Module is not grounded.
Verify module is securely grounded to metal chassis of stove.