A pressure regulator sized for this unit is included. 
1. 
 
Natural gas 5.0” W.C., propane gas 10.0” W.C.
Gas line connecting to range must be 3/4” or larger. If 
2. 
 
fl exible connectors are used, the inside diameter must be
 
3/4” or larger.
An adequate ventilation system is required for commercial
3. 
 
cooking equipment. Information may be obtained by 
 
writing to the National Fire Protection Association, 
 
1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org. 
 
When writing, refer to NFPA No. 96.
These units are manufactured for installation in 
4. 
 
accordance with ANSZ223.1A (latest edition), National 
 
Fuel Gas Code. Copies may be obtained from The 
 
American Gas Association, 400 N Capitol St. NW, 
 
Washington, DC 20001, www.AGA.org.
Clearances
5.  
Rear 
 
Sides
 Combustible 
6” 
10”
 
Standard Oven Non-combustible  
0”  
0”
 
Convection Oven Non-combustible 
Min. 4”  
0”
For proper combustion, install equipment on adjustable 
6. 
 
legs or casters provided with unit.
For proper combustion, install equipment on adjustable
7. 
 
legs or casters provided with unit.
NOTE:  In line with its policy to continually improve its product, 
Wolf Range Company reserves the right to change materials 
and specifi cations without notice.
Specify type of gas when ordering. Specify altitude when 
above 2,000 feet.
INSTALLATION INSTRUCTIONS
TOP
CONFIGURATION
MODEL 
NUMBER
DESCRIPTION
TOTAL INPUT 
BTU / HR
SHIPPING WEIGHT
LBS / KG
C24S-4
4 Burners / 1 Standard Oven
140,000
350 / 159
C24S-2FT12
2 Burners / 12” Fry Top / 1 Standard Oven
100,000
375 / 170
C24S-FT24
24” Fry Top / 1 Standard Oven
60,000
390 / 177