Wolf C48S-4B24GN Fascicule

Page de 2
R E S T A U R A N T   R A N G E S
P.O. Box 696 
  Louisville, KY 40201 
  Toll-free: 1-800-814-2028 
  Local: 502-778-2791 
  Quote & Order Fax: 1-800-444-0602
 
a division of ITW Food Equipment Group LLC
F45339 (04/13)
NOTE: In line with its policy to continually improve its products, Wolf reserves the right to change materials and specifications without notice.
CHALLENGER XL GAS RESTAURANT RANGE
4 OPEN BURNERS / 24" GRIDDLE 
48" WIDE GAS RANGE
TOP 
CONFIGURATION
MODEL  
NUMBER
DESCRIPTION
TOTAL INPUT  
BTU / HR
SHIPPING WEIGHT 
LBS / KG
C48S-4B24GN
1 Standard Oven / 4 Burners / 24" Griddle / Natural Gas
195,000
720 / 327
C48S-4B24GP
1 Standard Oven / 4 Burners / 24" Griddle / Propane
195,000
720 / 327
C48C-4B24GN
1 Convection Oven / 4 Burners / 24" Griddle / Natural Gas
195,000
780 / 355
C48C-4B24GP
1 Convection Oven / 4 Burners / 24" Griddle / Propane
195,000
780 / 355
This appliance is manufactured for commercial use only and is not intended for home use.
INSTALLATION INSTRUCTIONS
5. 
Clearances 
Rear  
Sides
 Combustible 
6" 
10"
 
Standard Oven Non-combustible  
0"  
0"
 
Convection Oven Non-combustible 
Min. 4"  
0"
6. For proper combustion, install equipment on adjustable 
 
legs or casters provided with unit.
 
NOTE:  In line with its policy to continually improve its product, 
Vulcan reserves the right to change materials and specifications 
without notice.
Specify type of gas when ordering. 
Specify altitude when above 2,000 feet.
1.  A pressure regulator sized for this unit is included. Natural  
gas 5.0" W.C., propane gas 10.0" W.C.
2.  Gas line connecting to range must be 1" or larger. If  flexible 
connectors are used, the inside diameter must be 1" or larger.
3.  An adequate ventilation system is required for commercial 
cooking equipment. Information may be obtained by writing 
to the National Fire Protection Association, 1 Batterymarch 
Park, Quincy, MA 02269, www.NFPA.org. When writing,  refer 
to NFPA No. 96.
4.  These units are manufactured for installation in  accordance 
with ANSZ223.1A (latest edition), National Fuel Gas Code. 
Copies may be obtained from The American Gas Association, 
400 N Capitol St. NW, Washington, DC 20001, www.AGA.org.