Smeg A36A6PXAA Manuel D’Utilisation

Page de 12
 
Instructions for the installer
 
 
 
 
4. FINAL OPERATIONS 
Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “3.2 Burner and 
nozzle characteristics table”. 
 
 
 
 
After adjustment to a different kind of gas from the one for which the 
cooker has been tested, replace the plate inside the heating 
compartment with one corresponding to the new kind of gas. This plate 
can be obtained from your nearest Authorised Assistance Centre. 
 
 
 
4.1  Adjustment of minimum for natural gas 
 
Light the burner and take it to the minimum. 
Remove the gas tap knob and turn the 
adjustment screw inside or at the side of the tap 
shaft (depending on the model) until there is a 
regular minimum flame. Replace the knob and 
check burner flame stability: (rapidly turning the 
knob from maximum to minimum position, the 
flame should not go out). Repeat the operation on 
all the gas taps. 
 
 
4.2  Regulation of minimum for LPG 
 
To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model). 
The diameters of the by-passes for each burner are given in table “3.2 
Burner and nozzle characteristics table”. 
 
 
 
4.3  Lubrication of gas taps 
 
With time it may happen that the gas taps get blocked and hard to turn. 
Clean them inside and re-grease them. This operation must be done 
by a specialised technician.
 
23