4-CONDUCTOR POWER CORD INSTALLATION 
Use this method for new installations and whenever 4-conductor installation is required. 
 
•  Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will 
then be accessible. 
•  Remove the knockout ring (1 3/8”) located on bracket directly below the terminal block. To remove the knockout, use a 
pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed. 
•  Assemble a U.L.-listed strain relief in the opening. 
•  Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal 
block. 
•  Use only ring terminals to connect the power supply. 
•  Remove the ground-link screw from the range frame. Save the ground-link screw. Bend the ground link away from the 
range so that it does not contact the range. 
•  Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must 
be attached first and must not contact any other terminal. 
•  Use a ¼” nut driver and remove the hex washer head nuts from the terminal block. 
•  Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for 
proper electrical connection.  
•  Tighten the strain relief screws. 
•  Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire 
cover and main back. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
TERMINAL BLOCK
CONNECT LINE 2
HERE
CONNECT LINE 1
HERE
RED WIRE
BLACK WIRE
CONNECT NEUTRAL
HERE
GROUND STRAP
(NEUTRAL)
WHITE WIRE
TERMINAL BLOCK
CONNECT LINE 2
HERE
RED WIRE
GROUND STRAP
CONNECT NEUTRAL
HERE
BLACK WIRE
CONNECT LINE 1
HERE
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
GREEN 
GROUND WIRE
(NEUTRAL)
WHITE WIRE