Danby DER2009W Manuel D’Utilisation
4-CONDUCTOR POWER CORD INSTALLATION
Use this method for new installations and whenever 4-conductor installation is required.
• Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will
• Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will
then be accessible.
• Remove the knockout ring (1 3/8”) located on bracket directly below the terminal block. To remove the knockout, use a
pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.
• Assemble a U.L.-listed strain relief in the opening.
• Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal
• Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal
block.
• Use only ring terminals to connect the power supply.
• Remove the ground-link screw from the range frame. Save the ground-link screw. Bend the ground link away from the
• Remove the ground-link screw from the range frame. Save the ground-link screw. Bend the ground link away from the
range so that it does not contact the range.
• Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must
be attached first and must not contact any other terminal.
• Use a ¼” nut driver and remove the hex washer head nuts from the terminal block.
• Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for
• Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for
proper electrical connection.
• Tighten the strain relief screws.
• Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire
• Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire
cover and main back.
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
TERMINAL BLOCK
CONNECT LINE 2
HERE
CONNECT LINE 1
HERE
RED WIRE
BLACK WIRE
CONNECT NEUTRAL
HERE
GROUND STRAP
(NEUTRAL)
WHITE WIRE
TERMINAL BLOCK
CONNECT LINE 2
HERE
RED WIRE
GROUND STRAP
CONNECT NEUTRAL
HERE
BLACK WIRE
CONNECT LINE 1
HERE
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
GREEN
GROUND WIRE
(NEUTRAL)
WHITE WIRE