Furuno 1734C Instruction De Maintenance

Page de 241
7. CUSTOMIZING YOUR UNIT 
 7-37
7.9.3  Sounding range, zoom range, bottom lock range 
This paragraph shows you how to set custom ranges for basic range, zoom range (marker 
and bottom zoom) and bottom lock range. All default basic ranges are restored whenever 
the unit of depth measurement is changed. Therefore, change the depth unit before 
changing the basic ranges. 
 
1.  Show the sounder display, then press the MENU key to open the main menu. 
2.  Press the SOUNDER RANGE SETUP soft key to show the SOUNDER RANGE SETUP 
menu. 
RANGE
     SETUP
RETURN
EDIT
RANGE 1
15 ft
RANGE 2
30 ft
RANGE 3
60 ft
RANGE 4
120 ft
RANGE 5
200 ft
RANGE 6
400 ft
RANGE 7
1000 ft
RANGE 8
4000 ft
ZOOM RANGE
10 ft
BOTTOM LOCK RANGE
10 ft
 
Sounder range setup menu 
3.  Select the range to change, then press the EDIT soft key.   
4. Rotate the Cursor pad or ENTER knob to set range desired, then press the RETURN 
soft key. For basic range, set depth from lowest to highest; a range cannot be higher 
than its succeeding neighbor. 
5. Press the MENU key to finish. 
Default basic ranges 
Range 8 
Range 1 
Range2 
Range 3 
Range 4
Range 5
Range 6
Range 7
ETR-6/10N ETR-30N 
5 m 
10 m 
20 m 
40 m 
80 m 
150 m 
300 m   
1200 m 
1500 m 
15 ft 
30 ft 
60 ft 
120 ft 
200 ft 
400 ft 
1000 ft 
4000 ft 
4500 ft 
3 fa 
5 fa 
10 fa 
20 fa 
40 fa 
80 fa 
150 fa 
650 fa 
900 fa 
3 P/B 
5 P/B 
10 P/B 
30 P/B 
50 P/B 
100 P/B 
200 P/B 
700 P/B 
900 P/B 
Zoom range and bottom-lock ranges 
Item Settings 
Default 
Setting 
Zoom Range 
2 m – 120 m, 7 ft – 400 ft, 
1 fa – 60 fa, 1 P/B – 700 P/B
10 m, 30 ft, 10 fa, 10 P/B 
Bottom-lock 
Range 
3 or 6 m, 10 or 20 ft, 2 or 3 
fa, 2 or 3 P/B 
6 m, 20 ft, 3 fa, 3 P/B