2. RADAR OPERATION 
 
2-30
Automatic acquisition area
45
°
 port
45
°
 starboard
2.0 - 2.5 nm
Automatic acquisition area 
2.  Press the TARGET soft key.   
3.  Place the cursor on the target to acquire. 
4.  Press the ACQ soft key. 
5.  Press the RETURN soft key to finish. 
 
The plot symbol changes over time as below. A vector appears about one minute after 
acquisition, indicating the target’s motion trend. 
At acquisition
1 min. after
acquisition
3 min. after
acquisition
01*
01*
01*
Vector
* = Target number shown when TARGET ID NUMBER is
      turned on in the ARP SETUP menu.
Target Number
 
ARP plot symbols 
Note:
 In case of the acquisition by an external ARP, the acquisition circle mark appears one 
minute after acquisition. 
 
Automatic acquisition 
The ARP can acquire up to ten targets 
automatically by setting an automatic 
acquisition area. When automatic acquisition is 
selected after acquiring targets manually, only 
the remaining capacity for targets may be 
automatically acquired. For example, if seven 
targets have been manually acquired, three 
targets may be automatically acquired.   
 
1. Press the MENU key to show the main 
menu. 
2.  Press the ARP SETUP soft key to show the ARP SETUP menu. 
3. Operate the Cursor pad to select AUTO ACQUISITION AREA. 
4.  Press the EDIT soft key to show the automatic acquisition area window. 
 AUTO ACQ. AREA
¤
¡
ON
OFF
 
Automatic acquisition area window 
5.  Select ON, then press the ENTER soft key.   
6. Press the MENU key to close the menu. An acquisition area of 2.0 to 2.5 miles in range 
and ±45º on either side of the heading line in bearing appears. 
 
Note:
 Targets being tracked in automatic acquisition are continuously tracked when 
switching to manual acquisition.