   10 SET AUDIO MODE
10-1
10
SET AUDIO MODE
The light acceptance quantity level for the EDM (SIGNAL), the atmospheric correction value (PPM), 
correction value of prism constant (PSM) and correction value of non-prism constant (NPM) are 
displayed in this mode.
When reflected light from the prism is received a buzzer sounds.  This function is good for easy 
collimation when the target is difficult to find.
Operating procedure
Operation
Display
1
Press the [F4] key to get the soft key page 2 in the 
distance measurement mode or page 3  in the 
coordinate measurement.
[F4]
2
Press the [F3](S/A) key to change to set audio 
mode.
The display indicates correction value of prism 
constant (PSM), non-prism constant (NPM) 
atmospheric correction (PPM) and reflection light 
level (SIGNAL).
[F3]
When receiving reflected light, buzzer sounds.
It is possible to stop the sound,  see Chapter 16 “SELECTING MODE” .
The [F1] to [F3] keys are used for setting atmospheric correction and prism constant.
To return to normal measuring mode, press the [ESC] key.
HR: 120°30'40" 
HD* 123.456 m
VD:   5.678 m
MEAS MODE  NP/P P1
OFSET S.O  S/A  P2
  
PSM:0.0   PPM   0.0
NPM:0.0   
SIGNAL:[
❙ ❙ ❙ ❙ ❙
]
PRISM PPM  T-P  –––