   6 SPECIAL MODE (Menu Mode)
6-5
6.1.2 Missing Line Measurement (MLM) 
Measurement for horizontal distance (dHD), slope distance (dSD), elevation (dVD) and horizontal 
bearing (HR) between two target prisms.
It is possible to enter the coordinate value directly or calculate from coordinate data file.
MLM mode has two modes.
1:  MLM-1 (A-B, A-C) :Measurement is A-B, A-C, A-D,......
2:  MLM-2 (A-B, B-C) :Measurement is A-B, B-C, C-D,......
It is necessary to set the direction angle of the instrument.
[Example]   MLM-1 (A-B, A-C) 
Procedure of MLM-2 (A-B, B-C) mode is completely same as MLM-1 mode
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
key to get the menu on page 2.
[MENU]
[F4]
2
Press the [F1] key.
[F1]
3
Press the [F2](MLM) key.
[F2]
4
Press the [F1] or [F2] key to select using
coordinate file.
[Example:F2 : DON’T USE]
[F2]
 
Prism A
Prism B
Prism C
Prism B
Prism A
Instrument
Instrument
  
MENU            2/3
 F1:PROGRAMS
 F2:GRID FACTOR
 F3:ILLUMINATION P
  
PROGRAMS        1/2
 F1:REM 
 F2:MLM
 F3:Z COORD.     P
  
MLM
 F1:USE FILE 
 F2:DON’T USE
  
GRID FACTOR
 F1:USE G.F.
 F2:DON’T USE