Topcon GPT-2000 Manuel D’Utilisation
7 DATA COLLECTION
7-19
7.6
Setting Parameter of Data Collect [CONFIG.]
In this mode, the following settings of data collect mode are possible.
●
Setting Items
●
How to Set Items
Example Setting: DATA CONFIRM : YES
Menu
Selecting Item
Contents
F1:DIST MODE
FINE / CRS(1) /
CRS(10)
Select Fine /Coarse(1) /Coarse(10) mode in distance
measurement mode.
The unit to be displayed is as follows.
Fine mode: 1mm (0.2mm)
Coarse (1) mode: 1mm
Coarse (10) mode: 10mm
measurement mode.
The unit to be displayed is as follows.
Fine mode: 1mm (0.2mm)
Coarse (1) mode: 1mm
Coarse (10) mode: 10mm
F2:HD/SD
HD/SD
Select the distance measurement mode Horizontal
Distance or Slope distance.
Distance or Slope distance.
F3:MEAS. SEQ.
N-TIMES /
SINGLE / REPEAT
Select to set measurement mode for distance
measurement.
measurement.
F1:DATA CONFIRM
YES/NO
It is possible to confirm the result of measuring data
before the data is recorded.
before the data is recorded.
F2:COLLECT SEQ.
[EDIT
→
MEAS] /
[MEAS
→
EDIT]
Select the procedure of data collection.
[EDIT
[EDIT
→
MEAS] :Measurement is carried out after
entering other data.
[MEAS
[MEAS
→
EDIT] :Measurement is carried out before
entering other data.
F3:NEZ AUTO. CALC
ON/OFF
It is possible to calculate coordinate value of data collected
and store it into coordinate data file in every data collection.
and store it into coordinate data file in every data collection.
Operating procedure
Operation
Display
1
Press the [F3] (CONFIG.) key from the data collect
menu 2/2.
The CONFIG menu 1/2 is shown.
menu 2/2.
The CONFIG menu 1/2 is shown.
[F3]
2
Press the [F4](P
↓
) key to display the CONFIG
menu 2/2.
[F4]
3
Press the [F1] (DATA CONFIRM) key.
[ ] indicates the current setting.
[ ] indicates the current setting.
[F1]
4
Press the [F1] (YES) key.
[F1]
5
Press the [F4] (ENTER) key.
[F4]
DATA COLLECT 2/2
F1:SELECT A FILE
F2:PCODE INPUT
F3:CONFIG. P
F1:SELECT A FILE
F2:PCODE INPUT
F3:CONFIG. P
↓
CONFIG. 1/2
F1:DIST MODE
F2:HD/SD
F3:MEAS. SEQ. P
F1:DIST MODE
F2:HD/SD
F3:MEAS. SEQ. P
↓
CONFIG. 2/2
F1:DATA CONFIRM
F2:COLLECT SEQ.
F3:NEZ AUTO. CALC P
F1:DATA CONFIRM
F2:COLLECT SEQ.
F3:NEZ AUTO. CALC P
↓
DATA CONFIRM
F1:YES
[F2:NO ]
ENTER
F1:YES
[F2:NO ]
ENTER
DATA CONFIRM
[F1:YES]
F2:NO
ENTER
[F1:YES]
F2:NO
ENTER