   17 CHECK AND ADJUSTMENT
17-10
17.3.7Adjustment of Vertical Angle 0 Datum
If when measuring  the vertical angle of target A at telescope position normal (direct) and reverse 
settings, the amount of normal and reverse measurements combined is other than 360° (ZENITH-0), 
half of the difference from 360° is the error amount from corrected 0 setting. Carry out adjustment. As 
adjustment for vertical angle 0 setting is the criteria for determining instrument coordinate origin, use 
special care for adjustment.
Operating procedure
Operation
Display
1
Level the instrument properly with the
plate level.
2
While pressing the [F1]key, turn power  switch ON.  
[F1]
+
Power ON 
3
Press the [F1] key.
[F1]
4
Collimate target A from the telescope properly in 
normal setting.  
Collimate A
(Normal)
5
Press the [F4](ENTER) key.
6
Collimate target A in reverse telescope setting.
[F4]
Collimate A
(Reverse)
7
Press the [F4](ENTER) key.
Measured value is set and  carry out normal angle 
measurement. 
[F4]
8
Check that the total amount of normal and reverse 
angular travel  is 360° collimating the target A by 
normal and reverse positions.
  
ADJUSTMENT MODE  
 F1:V ANGLE 0 POINT
 F2:INST. CONSTANT
 F3:V0 AXIS      
  
V0 ADJUSTMENT
 <STEP-1> FRONT
 V:   90°00'00"
               ENTER
  
V0 ADJUSTMENT
 <STEP-2> REVERSE
 V:  270°00'00"
               ENTER
  
     <SET!>
  
V : 270°00'00" 
HR: 120°30'40"
0SET  HOLD  HSET P1