Topcon GPT-2005 Manuel D’Utilisation

Page de 168
 
3-3
 
   3 ANGLE MEASUREMENT
 
3.3.2 Setting a Horizontal Angle from the Keys
 
Make sure the mode is  Angle measurement
 
.
 
3.4
Vertical Angle Percent Grade(%) Mode
 
Make sure the mode is  Angle measurement
 
.
 
Operating procedure
Operation
Display
 
1
 
Collimate the target.
Collimate
 
2
 
Press the [F3](HSET) key.
[F3]
 
3
 
Input the required horizontal angle by
using keys. *1)
For example :70°40'20"
When completed, normal measuring from the 
required Horizontal angle is possible.
[F1]
70.4020
[F4]
 
Operating procedure
Operation
Display
 
1
 
Press the [F4](
 
 
) key to get the function on page 2.
[F4]
 
2
 
Press the [F3](V%) key. *1)
[F3]
*1) Every time pressing the [F3](V%) key, the display mode switches.
 
 
When the  measurement is carried out over ±45° (±100%) from the horizontal, the display shows 
<OVER>.
 V :  90°10'20"
 HR: 170°30'20"
0SET HOLD HSET P1
H ANGLE SET
 HR:
INPUT --- --- ENTER
1234 5678 90.-[ENT]
 V :  90°10'20"
 HR:  70°40'20"
0SET HOLD HSET P1
V :  90°10'20" 
HR: 170°30'20"
0SET HOLD HSET P1
TILT  REP  V%  P2
V :  -0.30   % 
HR: 170°30'20"
TILT  REP  V%  P2