   6 SPECIAL MODE (Menu Mode)
6-16
6.2
Setting the GRID FACTOR
GRID FACTOR can reset in this menu mode.
For more information, refer to Section 8.1.1”Setting the GRID FACTOR” 
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
key to get the menu on page 2.
[MENU]
[F4]
2
Press the [F2](GRID FACTOR) key.
[F2]
3
Press the [F3](YES) key. 
4
Press the [F1] (INPUT) key and enter Elevation. 
*1)    Press the [F4](ENT) key.
[F3]
[F1]
Enter ELEV.
[F4]
5
Enter Scale Factor in the same way.
[F1]
Enter Scale
[F4]
Grid Factor is displayed for 1 to 2 second and 
display returns to menu.
Input Range :Elevation     : –9,999 to +9,999 meter (–32,805 to +3,2805 ft, ft+in)
                     Scale Factor: 0.990000 to 1.010000
  
MENU            2/3
 F1:PROGRAMS
 F2:GRID FACTOR
 F3:ILLUMINATION P
  
GRID FACTOR
  =0.998843
 
>MODIFY?   [YES][NO]
GRID FACTOR
 ELEV.
1000 m
 SCALE:0.999000
INPUT –––  ––– ENTER  
1234 5678 90. –[ENT]
  
GRID FACTOR
 ELEV.:2000 m
 SCALE
1.001000
INPUT –––  ––– ENTER
  
GRID FACTOR
  =1.000686