Topcon GPT-2005 Manuel D’Utilisation

Page de 168
   8 LAYOUT
8-5
8.1.3 Setting Occupied Point 
Occupied point can be set by two setting methods as follow.
1) Setting from the coordinate data stored in the internal memory.
2) Direct key input of coordinate data.
Example setting :Setting the occupied point from the internal coordinate data file 
Operating procedure
Operation
Display
1
Press the [F1](OCC.PT INPUT) key from the 
Layout menu 1/2.
The previous data is shown.
[F1]
2
Press the [F1] (INPUT) key and enter PT#.  *1)
Press the [F4](ENT) key. 
[F1]
Enter PT#
[F4]
3
Enter INS.HT in the same way.
[F1]
Enter 
INS.HT
[F4]
The display returns to layout menu 1/2.
  
OCC.PT
 PT#:
INPUT LIST NEZ ENTER
  
OCC.PT
 PT#=PT-01
1234 5678 90.– [ENT]
INSTRUMENT HEIGHT
INPUT
INS.HT:   0.000 m
INPUT –––  ––– [ENT]
1234 5678 90.– [ENT]
  
LAYOUT          1/2
 F1:OCC.PT INPUT   
 F2:BACKSIGHT
 F3:LAYOUT      P