Castile Pellet Insert
5
Venting Systems
Figure 13.2
A.
Direct Connect With Outside Air
B.
Direct Connect Without Outside Air
NOTE:
In Canada, where passage through a wall or partition of 
combustible construction is desired, the installation shall 
conform to CAN/CSA-B365.
Outside Air
through
Rear Wall
Figure 13.1
Fire Risk.
Inspection of Chimney:
•  Masonry chimney must be in good condition.
•  Meets minimum standard of NFPA 211
•  Factory-built chimney must be 6 inch (152mm) 
UL103 HT.
WARNING
CAUTION
Never draw outside combustion air from:
•  Wall, floor or ceiling cavity
•  Enclosed space such as an attic or garage
NOTE:
  Illustrations reflect typical installations and are FOR 
DESIGN PURPOSES ONLY.
  Illustrations/diagrams are not drawn to scale.
  Actual installation may vary due to individual design 
preference.
NOTE;  Use metal plate 
around exhaust vent pipe 
and seal all edges with 
non-flammable insulation 
such as fiberglass, mineral 
wool or ceramic material.
Do not use high tempera-
ture caulking materials to 
seal any edge to prevent 
future serviceability.
NOTE: In Canada, only a full reline is 
allowed per ULC S-628, ORD ULC C1482.